產品說明0
Fluke 80 Clampmeter, Max Current 100A ac, 100A dc CAT II 600 V, CAT III 300 V
AC / DC current clamp, Fluke 80i-110S
AC / DC current clamp to expand the measuring ranges of Fluke SCOPE meters and oscilloscopes
Current ranges: | 0 → 10 A DC or AC Peak |
| 0 → 100 A DC or AC peak |
Output voltage: | 10 A range 100 mV/A |
| 100 A range 10 mV/A |
Basic accuracy (DC to 1 kHz): | <3% +50 mA (50 mA → 10 A) |
| <4% +50 mA (50 mA → 40 A) |
| <12% +50 A (40 A → 80 A) |
Bandwidth (-3 dB) | 100 kHz |
Max. Conductor diameter: | 11.8 mm |
Power source: | 9 V battery |
Dimensions: | 67 ´ 231 ´ 36 mm |
Weight: | 330 g |
Absolute Maximum DC Current Measurement | 100A dc |
Model Number | 80 |
Best DC Current Accuracy | ±3% + 50 mA |
Clamp Meter Type | Current |
Best AC Current Accuracy | ±3% +50 mA |
Battery Life | 55 h |
Power Source | Battery |
Width | 67mm |
Battery Type | 9V |
Maximum Conductor Size | 11.8mm |
Length | 231mm |
Jaw Capacity Busbars | 12.5mm |
Maximum Operating Temperature | +50°C |
Weight | 330g |
Safety Category | CAT II 600 V, CAT III 300 V |
Height | 36mm |
Functions Measured | AC Current, DC Current |
Safety Category Voltage | 300 V, 600 V |
Dimensions | 231 x 67 x 36mm |
Minimum Operating Temperature | 0°C |
Safety Category Level | CAT II, CAT III |